The DG5VC72AEPS1H80JA484 valve belongs to the DG5 Two-Stage Directional Valves series and is manufactured by Vickers. It directs hydraulic flow in automated machinery by using a pilot-operated spool that shifts oil between pressure, actuator, and tank lines. The valve tolerates a maximum working pressure of 350 bar on the supply and service ports p, a, b, and x, permitting installation in high-pressure systems. The tank port is rated for the same 350 bar so back-pressure conditions do not compromise the housing. A pilot stage pressure limit of 350 bar keeps the control section consistent with main-line ratings, while the drain port Y must remain below 210 bar to protect internal seals. The design passes up to 300 L/min, supporting cylinders or motors with high flow demand. A control volume of 7.28 cm³ from center to end allows quick partial travel, and 14.56 cm³ from end to end defines the fluid needed for a full stroke.
The electrical section is driven by a 24 V DC coil that consumes 30 W during operation. Continuous service is possible because the duty cycle is 100 % ED, and reliable actuation is maintained as long as coil voltage remains at or above 90 % of the rated value. Class F encapsulation shields the winding from moisture and vibration, while Class H wire insulation enables the winding to withstand higher internal temperatures. Safe exposure to ambient temperatures from −20 °C to 70 °C broadens application options in mobile or industrial settings. An IP65 enclosure rating blocks dust ingress and low-pressure water jets, protecting the connector and coil when mounted outside a control cabinet. These electrical characteristics allow the pilot spool to stay energized for extended periods without overheating, supporting machine cycles that require sustained directional control.
Ambient Temp Maximum (dc Coil)
70 C
Ambient Temp Minimum
-20 C
Coil Encapsulation
Class F
Coil Winding Class
Class H
Control Volume (center-to-end)
7.28 cm3
Control Volume (end-to-end)
14.56 cm3
Duty Cycle
100% ED
Enclosure Protection
IP65
Max Flow Rate
300 L/min
Max Pilot Pressure
350 bar
Max Working Pressure (p,a,b,x)
350 bar
Minimum Coil Voltage
90% of rated
Pilot Drain Port Y Max
210 bar
Power Consumption (dc)
30 W
Tank Port Max Pressure
350 bar
Voltage Rating
24 V DC