Bolts Required For Mounting
6
Coil Type
F (Flying Lead)
Coil Voltage
110V AC 50 Hz/120V AC 60 Hz
Interface
ISO 4401-08 (NFPA D08)
Max Flow Without Malfunction (210 Bar)
380 L/min (100 USgpm)
Max Mounting Bolt Torque
79 N·m (700 lbf·in)
Max Tank Line Pressure
210 bar (3000 psi)
Maximum Pilot Pressure
210 bar (3000 psi)
Mounting Bolt Thread
1/2-13 UNC
Pilot Tank Pressure Rating
100 bar (1450 psi)
Rated Pressure (p, A, B)
210 bar (3000 psi)
Recommended Flow
170 L/min (45 USgpm)
Shift Time (ac, Spool 6)
0.050 s
Spool Type
6 (P closed, A/B to T open)
Spool/spring Arrangement
C (Spring Centered)
Wiring Housing
W (1/2 NPT Thread)