The 060B016891 differential pressure switch is manufactured by Danfoss within the MP Differential Pressure Switches series and is intended to automate hydraulic circuits by opening or closing control relays when a preset pressure difference is reached. It covers a sensing span from –1 bar to 12 bar, allowing detection of slight vacuum conditions and moderate positive pressures in oil or water lines. A fixed differential of 0.65 bar keeps the contacts from chattering, while an adjustable switch differential of 0.2 bar lets the installer fine-tune the exact change needed before actuation. A 1/4 in flare pressure connection provides a tight metallic seal to standard tubing, and continuous service is allowed up to 17 bar working pressure withstanding 22 bar during pressure tests. Reliable operation is maintained between –40 °C and 60 °C ambient temperatures, so the unit can be mounted outdoors or near engines without auxiliary climate control.
The sensing bellows endures media temperatures to 100 °C, giving the switch compatibility with hot hydraulic oil. Electrically, a 250 V insulation rating and a 4 kV rated impulse voltage shield the relay contacts against line surges. After pressure falls below the reset point the relay opens within 90 s, which prevents rapid cycling in slowly bleeding systems. A 2 A short-circuit fuse limits fault current on the control line. The enclosure carries an IP20 rating that blocks accidental finger contact yet allows internal ventilation, and wiring enters through a Pg 13.5 cable gland to secure flexible conduit. These characteristics make the 060B016891 a compact component for hydraulic automation where moderate environmental protection, straightforward panel integration, and stable differential monitoring are required.
Ambient Temp Max
60 °C
Ambient Temp Min
-40 °C
Bellows Temp Max
100 °C
Cable Entry Size
Pg 13.5
Enclosure Rating
IP20
Fixed Differential
0.65 bar
Insulation Voltage
250 V
Lp Range Max
12 bar
Lp Range Min
-1 bar
Max Test Pressure
22 bar
Max Working Pressure
17 bar
Pressure Connection
1/4 in Flare
Rated Impulse Voltage
4 kV
Relay Release Time
90 s
Short Circuit Fuse
2 A
Switch Differential
0.2 bar