1-888-551-3082 | 1-919-443-0207 | sales@hydraulicpartsusa.com
You will get an email confirming we have received your inquiry.
A team member will review your request and be in touch concerning any questions or specifications.
You will receive a comprehensive quote tailored to your specific needs.
The 4WRZ16E1-150-7X/6EG24N9ETK4/M valve is part of the WRZ Proportional Directional Valves series produced by Bosch Rexroth for hydraulic automation tasks such as accurate actuator speed and position control. It operates on a supply voltage of 24 V DC, allowing direct interface with common machine controllers. The coil draws a maximum current of 1.5 A so drive cards must limit output accordingly. A coil resistance of 4.8 Ω at 20 °C defines the relationship between applied voltage and current for steady energization. Continuous service is possible because the duty cycle is rated at 100 %, preventing heat-related shutdowns during sustained commands. The coil insulation tolerates temperatures up to 150 °C, safeguarding performance in warm manifolds. A DIN EN 175301-803 plug provides a standardized electrical connection for quick field replacement. Protection class IP65 keeps dust and water jets away from the solenoid housing in typical plant environments. A concealed manual override (N9) lets technicians shift the spool mechanically when electrical power is unavailable.
The hydraulic section supports a maximum main valve flow of 460 l/min, giving the unit capacity for large cylinder circuits. Nominal flow is 150 l/min at a 10 bar pressure drop, which represents the expected rating for proportional metering in most systems. Main ports withstand operating pressures up to 350 bar so the valve can be installed in high-pressure lines without additional relief devices. Internal pilot oil supply and drain (ET) simplify plumbing because no external pilot hoses are needed. The tank port must remain below 30 bar, the specified limit for Port T when the internal drain path is used. An ISO 4401-07-06-0-94 mounting pattern allows direct bolting to widely available size 07 subplates. A command value overlap of 15 % defines the neutral deadband required for stable null positioning. The assembly weighs 13.4 kg, a factor to consider when selecting manifold supports and during installation.
Coil Resistance (20 °c)
4.8 Ω
Command Value Overlap
15%
Duty Cycle
100%
Electrical Connection
DIN EN 175301-803
Manual Override
Concealed (N9)
Max Coil Temperature
150 °C
Max Current
1.5 A
Max Main Valve Flow
460 l/min
Max Operating Pressure (main)
350 bar
Mounting Pattern
ISO 4401-07-06-0-94
Nominal Flow (∆p = 10 Bar)
150 l/min
Pilot Oil Supply/drain
Internal (ET)
Port T Max Pressure (int Drain)
30 bar
Supply Voltage
24 V DC
Type Of Protection
IP65
Weight
13.4 kg
Worldwide Shipping with FedEx and UPS.
We accept all major credit cards
1 year Hydraulic Parts USA warranty on ALL products
We are a Better Business Bureau A+ business