Biasing Current Adjustment Range
0...300 mA
Biasing Current Factory Setting
0 mA
Cable Diameter
4.5...11 mm
Clock Frequency At Maximum Current
200 Hz
Connection Resistance
20 kΩ
Current Consumption
< 1.7 A
Dimensions
See page 7
Maximum Cable Inductance
100 µH
Maximum Current Adjustment Range
0...1.8 A
Maximum Voltage
35 V
Minimum Coil Inductance
15 mH
Minimum Voltage
18 V
Mounting Type
M3 x 40 mm
Nominal Current
1.2 A
Operating Voltage
24 VDC
Permissible Operating Temperature Range (amplifier With Cable Gland)
-25 to +70 °C
Power Consumption
< 40 VA
Proportional Range For Command Value Input
0...10 V
Recommended Fuse
2 A (slow-blow)
Type Of Connection
4 screw terminals
Type Of Connection (solenoid)
Base to EN 175301-803
Type Of Protection
IP65 with cable mounted / mating connector mounted
Weight
0.125 kg