The DG4V3M2CMKUP5DH765 valve is built by Vickers for the DG4 Directional Valves series and controls hydraulic flow in automated machinery. It is solenoid operated so electric signals shift the spool instead of pilot fluid. A 2C closed-center, spring-centered spool blocks all work ports in neutral to hold actuators at rest. The coil runs on 24 VDC and draws 30 W, matching common control voltages while limiting heat rise. Class F encapsulation seals the winding, and class H insulation tolerates higher temperatures during service. A continuous 100 percent duty cycle allows the solenoid to stay energized indefinitely. The valve reaches its operating position in 60 ms when power is applied and returns in 40 ms after de-energizing, providing predictable switching for motion sequences.

A plain manual override lets technicians move the spool manually for setup or emergency operation. The hydraulic passages accept petroleum oils, and the oil must be kept at ISO 4406 cleanliness code 19/17/14 to protect internal clearances. Maximum flow is 80 L/min, supporting medium-capacity circuits, while port p, a, and b withstand 350 bar and the tank port endures 207 bar, enabling high-pressure work lines with a lower return line limit. The ISO 4401-AB-03-4-A mounting interface aligns with standard subplates so the valve can replace similar units without manifold changes. These hydraulic limits and mounting features complement the electrical and timing characteristics above, forming a balanced component for automated hydraulic control.

Technical Specifications

Actuation Type
Solenoid Operated

Coil Encapsulation Class
F

Coil Insulation Class
H

Coil Voltage Rating
24 VDC

Duty Cycle
100% ED

Fluid Cleanliness Code
ISO 4406 19/17/14

Fluid Compatibility
Petroleum Oils

Manual Override
Plain

Maximum Flow Rating
80 L/min

Maximum Port Pressure (p,a,b)
350 bar

Maximum Tank Pressure (t)
207 bar

Mounting Interface
ISO 4401-AB-03-4-A

Power Consumption
30 W

Response Time De-energize
40 ms

Response Time Energize
60 ms

Spool Type
2C (Closed Center, Spring Centered)

address-icon
1620 Old Apex Road
Cary, NC 27513, USA
phone-icon
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Shipping & Payment Options
DHL-logo FexEd-logo UPS-logo freight-icon

AmEx-icon Mastercard-icon Visa-icon wire-transfer-icon
To Speak to a sales representative for pricing & lead time
International

1-919-443-0207

Worldwide Shipping with FedEx and UPS.

We accept all major credit cards

1 year Hydraulic Parts USA warranty on ALL products

We are a Better Business Bureau A+ business