The DG4V36CMFTWLH760 valve belongs to the DG4 Directional Valves series from Vickers and is applied in hydraulic automation to switch flow paths between actuators. It is solenoid operated, and the wet armature design keeps moving parts lubricated by system fluid for reduced wear. The coil is encapsulated to Class F standards, while the winding insulation meets Class H temperature limits, so continuous operation is supported without thermal damage. A 24 VDC supply energizes the coil and the unit draws 30 W during actuation. Because the duty cycle is rated at 100 percent ED, the valve can remain energized indefinitely in demanding control loops. There is an indicator light that shows coil energization status for quick visual checks. Electrical connection is made through a terminal block with flying leads, simplifying field wiring changes, and the housing provides a 1/2 inch NPT thread for conduit entry.

A plain manual override lets technicians shift the spool mechanically during maintenance or if power is lost. Because the override is plain, it can be engaged directly by hand when the circuit is depressurized. The hydraulic section passes up to 80 L/min, equal to 21 US gpm, which suits medium-flow circuits in mobile or industrial equipment. Working ports P, A, and B tolerate 350 bar, or 5000 psi, while the tank port is limited to 210 bar, or 3000 psi; these limits define safe pressure boundaries for pumps, cylinders, and return lines. The valve attaches to subplates or manifolds with an ISO 4401-AB-03-4-A interface, corresponding to the CETOP 3 and NFPA D03 mounting pattern, so it can replace other valves that share these footprints without machining new manifolds. Taken together, the flow rating, pressure capability, and standardized mounting allow the valve to control directional flow reliably in compact hydraulic power units.

Technical Specifications

Actuation Type
Solenoid Operated

Coil Encapsulation
Class F

Coil Insulation Class
Class H

Duty Cycle
100% ED

Electrical Connection
Terminal Block (Flying Leads)

Electrical Supply
24 VDC

Indicator Light
Yes

Manual Override
Plain

Maximum Flow
80 L/min (21 USgpm)

Maximum Pressure (p/a/b)
350 bar (5000 psi)

Maximum Tank Port Pressure
210 bar (3000 psi)

Mounting Interface
ISO 4401-AB-03-4-A

Mounting Pattern
CETOP 3 / NFPA D03

Power Consumption
30 W

Solenoid Type
Wet Armature

Wiring Housing Thread
1/2 in NPT

address-icon
1620 Old Apex Road
Cary, NC 27513, USA
phone-icon
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Shipping & Payment Options
DHL-logo FexEd-logo UPS-logo freight-icon

AmEx-icon Mastercard-icon Visa-icon wire-transfer-icon
To Speak to a sales representative for pricing & lead time
International

1-919-443-0207

Worldwide Shipping with FedEx and UPS.

We accept all major credit cards

1 year Hydraulic Parts USA warranty on ALL products

We are a Better Business Bureau A+ business