The DG4V36BMP7H750JA100 valve belongs to the DG4 Directional Valves series manufactured by Vickers for hydraulic motion control in industrial automation systems. With spool 6 installed, the center condition blocks the P port while routes A and B to T, allowing the pump flow to be isolated and the actuator lines to unload when the valve is centered. Its spring-offset, end-to-center spool arrangement returns the element to the defined neutral position when solenoid power is removed. The unit mounts on an ISO 4401-03 (CETOP 3, NFPA D03) interface, enabling interchange with common subplates. Proper seating requires tightening the mounting bolts to 4.5–6.0 N·m. The P, A, and B ports tolerate 350 bar (5075 psi), while the T port is limited to 207 bar (3000 psi), establishing the pressure boundaries for circuit design.
Electrical actuation is provided by a 24 V DC solenoid that uses a top-exit flying-lead coil designated KU. The coil draws 30 W, and continuous service is supported by a 100 % ED duty rating. Supply voltage must remain at least 90 % of the rated value to guarantee reliable shifting. Packard Weatherpak male pins serve as the electrical connector, allowing sealed attachment in mobile or outdoor machinery. The coil is encapsulated with Class F insulation to withstand elevated temperatures, and the internal windings are built to Class H standards for further thermal margin.
Center Condition (spool 6)
P Blocked, A & B To T
Coil Type
Top Exit Flying Leads (KU)
Coil Voltage
24 VDC
Dc Coil Power
30 W
Duty Rating
100% ED
Electrical Connector
Packard Weatherpak Pins (Male)
Encapsulation Insulation Class
Class F
Mounting Bolt Torque
4.5–6.0 N·m
Mounting Interface
ISO 4401-03 (CETOP 3, NFPA D03)
P, A & B Port Max Pressure
350 bar (5075 psi)
Permissible Voltage (min)
90% Rated
Spool/spring Arrangement
Spring Offset, End To Center
T Port Max Pressure
207 bar (3000 psi)
Winding Insulation Class
Class H