1-888-551-3082 | 1-919-443-0207 | sales@hydraulicpartsusa.com

Vickers | DG4V36BMP7H750JA100

DG4V36BMP7H750JA100

Request a Quote

  Call For Quote
Repair Options Available
Worldwide Delivery
1-Year Warranty

What Happens Next?

1
Email Confirmation

You will get an email confirming we have received your inquiry.

2
Dedicated Account Manager

A team member will review your request and be in touch concerning any questions or specifications.

3
Quote Delivered

You will receive a comprehensive quote tailored to your specific needs.

The DG4V36BMP7H750JA100 valve belongs to the DG4 Directional Valves series manufactured by Vickers for hydraulic motion control in industrial automation systems. With spool 6 installed, the center condition blocks the P port while routes A and B to T, allowing the pump flow to be isolated and the actuator lines to unload when the valve is centered. Its spring-offset, end-to-center spool arrangement returns the element to the defined neutral position when solenoid power is removed. The unit mounts on an ISO 4401-03 (CETOP 3, NFPA D03) interface, enabling interchange with common subplates. Proper seating requires tightening the mounting bolts to 4.5–6.0 N·m. The P, A, and B ports tolerate 350 bar (5075 psi), while the T port is limited to 207 bar (3000 psi), establishing the pressure boundaries for circuit design.

Electrical actuation is provided by a 24 V DC solenoid that uses a top-exit flying-lead coil designated KU. The coil draws 30 W, and continuous service is supported by a 100 % ED duty rating. Supply voltage must remain at least 90 % of the rated value to guarantee reliable shifting. Packard Weatherpak male pins serve as the electrical connector, allowing sealed attachment in mobile or outdoor machinery. The coil is encapsulated with Class F insulation to withstand elevated temperatures, and the internal windings are built to Class H standards for further thermal margin.

Technical Specifications

Center Condition (spool 6)
P Blocked, A & B To T

Coil Type
Top Exit Flying Leads (KU)

Coil Voltage
24 VDC

Dc Coil Power
30 W

Duty Rating
100% ED

Electrical Connector
Packard Weatherpak Pins (Male)

Encapsulation Insulation Class
Class F

Mounting Bolt Torque
4.5–6.0 N·m

Mounting Interface
ISO 4401-03 (CETOP 3, NFPA D03)

P, A & B Port Max Pressure
350 bar (5075 psi)

Permissible Voltage (min)
90% Rated

Spool/spring Arrangement
Spring Offset, End To Center

T Port Max Pressure
207 bar (3000 psi)

Winding Insulation Class
Class H

address-icon
1620 Old Apex Road
Cary, NC 27513, USA
phone-icon
Toll Free: 1-888-551-3082
International: 1-919-443-0207
Shipping & Payment Options
DHL-logo FexEd-logo UPS-logo freight-icon

AmEx-icon Mastercard-icon Visa-icon wire-transfer-icon
To Speak to a sales representative for pricing & lead time
International

1-919-443-0207

Worldwide Shipping with FedEx and UPS.

We accept all major credit cards

1 year Hydraulic Parts USA warranty on ALL products

We are a Better Business Bureau A+ business