1-888-551-3082 | 1-919-443-0207 | sales@hydraulicpartsusa.com
You will get an email confirming we have received your inquiry.
A team member will review your request and be in touch concerning any questions or specifications.
You will receive a comprehensive quote tailored to your specific needs.
The 4WE6D6X/OFEG48NXEZ2/V directional valve is manufactured by Bosch Rexroth within the WE Directional Spool Valves series. It directs pressurized oil to selected actuator ports so automated hydraulic systems can extend, retract, or hold loads on demand. The valve bolts to subplates that match the NFPA T3.5.1 D03 mounting interface, which simplifies field replacement. Its porting pattern follows ISO 4401-03-02-0-05 to maintain channel alignment with standard manifolds. Ports P, A, and B are rated for 350 bar, enabling the unit to manage high working pressures, while the T port is restricted to 210 bar to preserve return-line integrity. A maximum flow of 80 l/min supports medium-sized cylinders without excessive pressure drop. FKM seal material resists mineral oils and elevated temperature, reducing leakage over time. System fluid must remain cleaner than ISO 4406 class 20/18/15 so the spool surfaces are not damaged by particulate contamination.
The electromagnetic actuation package is specified for a 48 V DC coil, allowing the valve to run from common low-voltage supplies on mobile or industrial equipment. The coil draws 0.66 A at the nominal 30 W power level, so panel designers can size conductors and fuses accurately. A voltage tolerance of ±10 % keeps the magnetic force within range during supply fluctuations. Continuous energization is possible because the duty cycle is 100 % ED, eliminating the need for cool-down intervals. Coil surface temperature may reach 120 °C before derating is required, providing a clear thermal limit for enclosure ventilation planning. When the driver circuit switches off, overvoltage is limited to 500 V to prevent insulation breakdown. The solenoid can shift the spool up to 4.2 times per second, defining the maximum control frequency for rapid cycling applications. These electrical characteristics ensure predictable response when the valve is integrated into closed-loop hydraulic automation.
Cleanliness Class
ISO 4406 20/18/15
Coil Voltage
48 V DC
Duty Cycle
100% ED
Max Coil Surface Temperature
120 C
Max Switch-off Overvoltage
500 V
Max Switching Frequency
4.2 1/s
Maximum Flow (dc)
80 l/min
Maximum Operating Pressure (p/a/b)
350 bar
Maximum Operating Pressure (t)
210 bar
Mounting Interface
NFPA T3.5.1 D03
Nominal Power (dc)
30 W
Porting Pattern
ISO 4401-03-02-0-05
Rated Coil Current
0.66 A
Seal Material
FKM
Voltage Tolerance
±10%
Worldwide Shipping with FedEx and UPS.
We accept all major credit cards
1 year Hydraulic Parts USA warranty on ALL products